Canon/Toshiba CT Scanner Comparison Chart

ManufacturerCannon/ToshibaCannon/ToshibaCannon/ToshibaCannon/ToshibaCannon/ToshibaCannon/ToshibaCannon/ToshibaCannon/ToshibaCannon/ToshibaCannon/Toshiba
ModelLarge BoreAquillion 16Aquilion ONEAquilion PrecisionAquilion PRIME SPAquilion Lightning SERIESAquilion LightningExceed LBAsteion 4Aquilion Start
Detectors, typeSolid-state Gd(2)O(2)SSolid-state Gd(2)O(2)SPUREViSION Solid State TechnologyUltra High ResolutionPUREViSION Solid State TechnologyPUREViSION Solid State TechnologyPUREViSION Solid State TechnologyPUREVision solid-state4-slice detectorsPUREViSION Solid State Technology
No. of rows4040160 and 320 (optional in-field upgradeable)4040 and 80 (optional in-field upgrade avaialable)40 and 80 (optional in-field upgradeable)161604040
Gantry dimensions, H x W x D, (cm)210 x 230 x 101195 x 233 x 96192.5 x 227 x 96192.5 X 227 X 96187 X 215 X 87191 X 205 X 96191 X 205 X 96150 x 160 x 100156 x 160 x 120195 x 233 x 96
Gantry weight, (kg)1900175023602410180014501350236033002000
Gantry aperture, (cm)90727878787878907078
Heat storage, HU7.5 MHU7.5 MHU7.5 MHU5.7 MHU7.5 MHU5.0 MHU5.0 MHU1005007.5
Tube CoolingOil/AirOil/AirOil/airOil/airOil/airOil/airOil/airAir/liquidAir/WaterOil/Air
kW output60602/100* *optional7260/7250.4 (112 kW equivalent with AIDR 3D)50.4 (112 kW equivalent with AIDR 3D)1208060
mA Range10 to 58010 to 58010- 600, 900* (kV dependaent 10-50 in increments of 5, >50 in increments of 10) *optional10-600 (kV dependant, 10-50 in increments of 5, >50 in increments of 10)10-600 (kV dependant, 10-50 in increments of 5, >50 in increments of 10)10-420 (10-50 in increments of 5, >50 in increments of 10)10-420 (10-50 in increments of 5, >50 in increments of 10)10 to 60010 to 50010 to 500
Max scan volume, cm175175195195195195195230100183
Max load capacity with accuracy, kg205 +/- 0.25, option 230 +/- 0.25205 +/- 0.25, option 230 +/- 0.25315 (up to 0.25 mm)315 (up to 0.25 mm)315 (up to 0.25 mm)315 (up to 0.25 mm)315 (up to 0.25 mm)205230220
Scan FOVs, (cm)18, 24, 32, 40, 55, 70, 85 (extended)18, 24, 32, 40, 5024, 32, 5032, 5018, 24, 32, 40, 5032, 5018, 24, 32, 39, 5018, 24, 32, 40, 50, 60, 70, 85 (extended)34, 40, 46, 56, & 7018, 24, 32, 40, 50, 60, 70, 85 (extended)
Reconstruction matrices512 x 512512 x 512512 x 512512 x 512 , 1,024 x 1,024512 x 512512 x 512 ,512 x 512512 x 512, 1024 x 1024, 2048 x 2048512 x 512, 1024 x 1024, 2048 x 2048, 4096 x 4096, & 8192 x 8192512 x 512, 1024 x 1024,
Dose-modulation techniqueYesYesXYZ and optional ECG Modulation, AIDR 3-D enhanced integrated, AiCE deep learning reconstruction (optional)XYZ and optional ECG Modulation, AIDR 3-D enhanced integrated, AiCE deep learning reconstruction (optional)XYZ and optional ECG modulation, AIDR 3-D enhanced integrated, AiCE deep learning reconstruction (optional)XYZ and optional ECG modulation, AIDR 3D enhanced integratedAIDR 3D enhanced integrated; XYZ modulationSureExposure tube current modulation, AIR, DVCSureExposure, AIR, DVC, ASIR, & Volumetric Rendering (VR)Automatic Exposure Control (AEC),
3D-mA Modulation
Suggested room size (m2)21 (19 min.)21 (19 min.)Scan room: 22.8 (19 short couch)Scan room: 21 (19 short couch)Scan room: 16.8 (14.8 short couch)Scan Room: 14.5 m2 (11.5 m2 short couch)Scan Room: 14.5 m2 (11.5 m2 short couch)151525
No. of Slices16163201608040,80,160160160416,32
kVp (Range)80,100,120,13580 to 14080 to 14080 to 14070 to 14080 to 14070 to 14070 to 14080 to 14080 to 140

Updated on 4.8.2025

Back To Top