GE Healthcare (Short/Compact) MRI Systems

Manufacturer GE Healthcare GE Healthcare GE Healthcare GE Healthcare GE Healthcare GE Healthcare GE Healthcare
Model  Signa Infinity 1.0 T Signa Infinity 1.5 TwinSpeed w/ Excite Signa Infinity 1.5 w/ Excite Signa HDe 1.5 T Signa HDx 1.5 T Signa HDx 3.0 T Signa Contour/i 0.5 T
Clinical Application Whole body Whole body Whole body Whole body  Whole body Whole body Whole body
Configuration Short Bore Short Bore Short Bore Short Bore Compact  Short Bore Compact Short Bore Compact Compact
Synchronization ECG/peripheral, respiratory gating ECG/peripheral, respiratory gating ECG/peripheral, respiratory gating, (SmartPrep, SmartStep) ECG/peripheral, respiratory gating, (SmartPrep, SmartStep) ECG/peripheral, respiratory gating, (SmartPrep, SmartStep) ECG/peripheral, respiratory gating ECG/peripheral, respiratory gating 
Imaging Modes Localizer, single, multislice, volume, fast, POMP, multi slab, cine 
Localizer, single, multislice, volume, fast, POMP, multi slab, cine  Localizer, single, multislice, volume, fast, POMP, multi slab, cine  2D single slice, multislice, & 3D volume images, multi slab, cine  2D single slice, multislice, & 3D volume images, multi slab, cine   Localizer, single, multislice, volume study, fast scan, multi slab, cine Localizer, single, multislice, volume, fast, POMP, multi slab
FOV 1 cm to 48 cm continuous 1 cm to 48 cm continuous 1 cm to 48 cm continuous   1 cm to 48 cm continuous 1 cm to 48 cm continuous 1 cm to 48 cm continuous 1 cm to 48 cm continuous
Magnet Type Superconducting  Superconducting  Superconducting  Superconducting  Superconducting  Superconducting  Superconducting
Bore Diameter 60 cm
60 cm
 60 cm
 N/A N/A  60 cm  60 cm
Magnet Weight 3613 kg 3863 kg  3863 kg  N/A N/A  12000 kg  N/A
H*W*D 172 x 208 x 216 cm 172 x 208 x 216 cm  172 x 208 x 216 cm  N/A N/A  240 x 2216,6 x 201,6 cm N/A
Power Requirements 480 or 380/415 480 or 380/415  480 or 380/415  480 or 380/415 480 or 380/415 480 or 380/415, 3-phase II 480 or 380/415 V
Cooling System Closed-loop water-cooled gradient Closed-loop water-cooled gradient Closed-loop water-cooled gradient Closed-loop water-cooled gradient Closed-loop water-cooled gradient Closed-loop water-cooled gradient Closed-loop water-cooled gradient
 Cryogen Use Less than 0.3 L/hr liquid helium Less than 0.3 L/hr liquid helium Less than 0.3 L/hr liquid helium  Less than 0.3 L/hr liquid helium Less than 0.3 L/hr liquid helium  0.3 L/hr helium N/A
 Field Strength  1.0 T  1.5 T  1.5 T  1.5 T 1.5 T  3.0 T  0.5 T
 Strength  SmartSpeed 23 mT/m, HiSpeed Plus 33 m/Tm Zoom 40 m/Tm, whole body 23 mT/m SmartSpeed 23 mT/m, HiSpeed Plus 33 m/Tm, EchoSpeed Plus 33 mT/m  N/A N/A 25-50 mT/m SmartSpeed 23 mT/m, HiSpeed Plus 33 m/Tm
 5 Guass Fringe Field 4.0 m x 2.8 m axial x radial 4.0 m x 2.8 m axial x radial  4.0 m x 2.8 m axial x radial N/A N/A  2.8 m/5.0 m  N/A
*Data shown here may not be accurate and is based on equipment seen in the secondary market. See manufacturers for exact data
**Similar devices are manufactured by vendors other than the MRI manufacturer