Philips Healthcare Computed Tomography (CT) Scanners

Manufacturer Philips Healthcare  Philips Healthcare  Philips Healthcare  Philips Healthcare  Philips Healthcare  Philips Healthcare 
Model Brilliance iCT Brilliance 16-slice (8.0 MHU)  MX 16-slice Ingenuity CT  Brilliance 64-channel with Essence technology Brilliance Big Bore Oncology 
Detectors, type Solid-state GOS  Solid-state GOS  16,128 elements: solid-state GOS  Solid-state GOS with BIP HiLight ceramic matrix II   Solid-state GOS 
No. of rows 64 - 128 spherical detectors with 2Danti-scatter  16  16  64 (128)  64 16 
Gantry dimensions, H x W x D, cm 221 x 89 x 189  203 x 239 x 94   189 x 221 x 89  203 x 238 x 94  203 x 238 x 93  200 x 252 x 97
Gantry weight, kg 2570  1764 1850  1941 1941 2043
Gantry aperture, cm 70 70 70 70 70 85
Heat storage, HU 30,000,000 eff.  8 (MRC technology)  5 MRC Ice (30 MHU eff.)  MRC 8 MHU (26 MHU eff.)  MRC 8 MHU (26 MHU eff.)
Tube Cooling Air Oil/Air Oil/Air Air Air Air
kW output 100-120 60 50 80  60 60
mA Range 10 to 833 / 1000 20 to 500 in 1mA increments 20 to 420 in 1 mA increments 20 to 667 in 1mA increments  20 to 500 in 1mA increments 20 to 500 in 1mA increments
Max scan volume, cm 175 175 150 185 (max. table travel)  175 (max. table travel)  175 (max. table travel) 
Max load capacity with accuracy, kg 204 (295 optional)  204 +/- 0.25 200 +/- 0.25  204 (295) 204 (295) 204 (295)
 Scan FOVs, cm 5 to 50 reconstructed FOV  Up to 50 Up to 50 50, 25 50, 25 60
 Reconstruction matrices  512, 768, 1024  512 x 512, 768 x 768, 1024 x 1024  512 x 512, 768 x 768, 1024 x 1024  5,122; 7,682; 10,242  5,122; 7,682; 10,242  5,122; 7,682; 10,242
 Dose-modulation technique DDOM, ZDOM, ASC DoseRight ACS (automatic currentselection), DoseRight D-DOM (rotationaldose modulation), DoseRight Z-DOM (longitudinal dose modulation) DoseRight ACS (automatic current selection), DoseRight DOM (rotational and longitudinal dose modulation)  Yes, angular and longitudinal (Z-DOM) dose modulation techniques Yes, angular and longitudinal (Z-DOM) dose modulation techniques  Yes, angular (D-DOM) and longitudinal
(Z-DOM) dose modulation techniques
 Suggested room size, m2 25 N/S N/S 26 (36 optimal) 26 (36 optimal) 26 (36 optimal)
*Data shown here may not be accurate and is based on equipment seen in the secondary market. See manufacturers for exact data
**Similar devices are manufactured by vendors other than the CT manufacturer