Other CT Scanners Comparison Chart

Manufacturer Neurologica Corp. Toshiba Toshiba Fujifilm Medical Systems U.S.A Hitachi Healtdcare Americas Hitachi Healtdcare Americas Hitachi Healtdcare Americas Neusoft Medical System Neusoft Medical System Neusoft Medical System Neusoft Medical System Fujifilm Medical Systems U.S.A
Model CereTom Large Bore Aquillion 16 Persona CT Scenaria View Supria True64 Supria Plus NeuViz Prime NeuViz 128 NeuViz 64 In Neuviz 16 Essence Scenaria View - Focus Edition
Detectors, type Solid-state Solid-state Gd(2)O(2)S Solid-state Gd(2)O(2)S Solid state GOS (gadolinium oxysulfide) Hi-speed solid state ceramic Hi-speed solid state ceramic Hi-speed solid state ceramic Solid-state GOS ceramic Solid-state GOS ceramic Solid-state GOS ceramic Solid-state GOS ceramic Hi-speed solid state ceramic
No. of rows 8 40 40 64 and 128 (optional in field upgrade) 64, 64/128-slice 64, 64/128-slice 32, 16/32-slice 64 64 32 32 64
Gantry dimensions, H x W x D, (cm) 63.3 x 52.7 x 28.7 210 x 230 x 101 195 x 233 x 96 201.9 x 249.2 x 107.4 204 x 235 x 88 185 x 199 x 92 184 x 199 x 92 191 x 93.8 x 219.8 191 x 93.8 x 219.8 192 x 89 x 224.4 192 x 89 x 224.4 204 x 235 x 88
Gantry weight, (kg) 362 1900 1750 1650 2235 1600 1600 1800 1800 1800 1800 2,235
Gantry aperture, (cm) 32 90 72 85 80 75 75 72 72 72 72 80
Heat storage, HU N/S 7.5 MHU 7.5 MHU 8.0MHU 7.5 MHU 5.0 MHU 5.0 MHU Unlimited (Equal to 30 MHU) 8 MHU 5 MHU 5.3MHU 7.5 MHU
Tube Cooling Air Oil/Air Oil/Air Oil/air Oil to air Oil to air Oil to air Oil to air Oil to air Oil to air Oil to air Oil to air, no chiller
kW output 1.05 60 60 80 (105 kW equivalent w. LISA) 84 48 48 100 80 50 50 84
mA Range 1 to 7 in 1 mA increments 10 to 580 10 to 580 10 to 660 10 to 700 10 to 400 10 to 400 10-833 mA 10-667 mA 30-420 mA 10-420 mA 10 to 700 mA
Max scan volume, (cm) 60 175 175 190 200 180 180 170 170 170 170
Max load capacity with accuracy, (kg) N/A 205 +/- 0.25, option 230 +/- 0.25 205 +/- 0.25, option 230 +/- 0.25 660 lb/300 kg 250 227 227 205 standard, 300 option 205 standard, 300 option 205 standard, 300 option 205 standard, 300 option 200
Scan FOVs, (cm) 25.3 18, 24, 32, 40, 55, 70, 85 (extended) 18, 24, 32, 40, 50 50 (extended FOV 85) 2 to 50 2 to 50 2 to 50 25, 33, 50 50 50 50 2 to 50
Reconstruction matrices 512 x 512, 1024 x 1024 512 x 512 512 x 512 512 x 512 512 x 512 512 x 512 512 x 512 512 x 512, 768 x 768, 1,024 x 1,024 512 x 512, 768 x 768, 1,024 x 1,024 512 x 512, 768 x 768, 1,024 x 1,024 512 x 512, 768 x 768, 1,024 x 1,024 512 x 512
Dose-modulation technique RadRedux noise reduction Yes Yes x, y, z dose modulation 3D mA modulation 3D mA modulation 3D mA modulation Yes Yes Yes Yes 3D AEC modulation
Suggested room size (m2) N/A 21 (19 min.) 21 (19 min.) ≥20.65m2 ≥35 ≥27 ≥27 27.6 27.6 27.6 27.6 ≥ 35 m2 recommended for system