Manufacturer |
Neurologica Corp. |
Toshiba |
Toshiba |
Fujifilm Medical Systems U.S.A |
Hitachi Healtdcare Americas |
Hitachi Healtdcare Americas |
Hitachi Healtdcare Americas |
Neusoft Medical System |
Neusoft Medical System |
Neusoft Medical System |
Neusoft Medical System |
Fujifilm Medical Systems U.S.A |
Model |
CereTom |
Large Bore |
Aquillion 16 |
Persona CT |
Scenaria View |
Supria True64 |
Supria Plus |
NeuViz Prime |
NeuViz 128 |
NeuViz 64 In |
Neuviz 16 Essence |
Scenaria View - Focus
Edition |
Detectors, type |
Solid-state |
Solid-state Gd(2)O(2)S |
Solid-state Gd(2)O(2)S |
Solid state GOS (gadolinium oxysulfide) |
Hi-speed solid state ceramic |
Hi-speed solid state ceramic |
Hi-speed solid state ceramic |
Solid-state GOS ceramic |
Solid-state GOS ceramic |
Solid-state GOS ceramic |
Solid-state GOS ceramic |
Hi-speed solid state
ceramic |
No. of rows |
8 |
40 |
40 |
64 and 128 (optional in field upgrade) |
64, 64/128-slice |
64, 64/128-slice |
32, 16/32-slice |
64 |
64 |
32 |
32 |
64 |
Gantry dimensions, H x W x D, (cm) |
63.3 x 52.7 x 28.7 |
210 x 230 x 101 |
195 x 233 x 96 |
201.9 x 249.2 x 107.4 |
204 x 235 x 88 |
185 x 199 x 92 |
184 x 199 x 92 |
191 x 93.8 x 219.8 |
191 x 93.8 x 219.8 |
192 x 89 x 224.4 |
192 x 89 x 224.4 |
204 x 235 x 88 |
Gantry weight, (kg) |
362 |
1900 |
1750 |
1650 |
2235 |
1600 |
1600 |
1800 |
1800 |
1800 |
1800 |
2,235 |
Gantry aperture, (cm) |
32 |
90 |
72 |
85 |
80 |
75 |
75 |
72 |
72 |
72 |
72 |
80 |
Heat storage, HU |
N/S |
7.5 MHU |
7.5 MHU |
8.0MHU |
7.5 MHU |
5.0 MHU |
5.0 MHU |
Unlimited (Equal to 30 MHU) |
8 MHU |
5 MHU |
5.3MHU |
7.5 MHU |
Tube Cooling |
Air |
Oil/Air |
Oil/Air |
Oil/air |
Oil to air |
Oil to air |
Oil to air |
Oil to air |
Oil to air |
Oil to air |
Oil to air |
Oil to air, no chiller |
kW output |
1.05 |
60 |
60 |
80 (105 kW equivalent w. LISA) |
84 |
48 |
48 |
100 |
80 |
50 |
50 |
84 |
mA Range |
1 to 7 in 1 mA increments |
10 to 580 |
10 to 580 |
10 to 660 |
10 to 700 |
10 to 400 |
10 to 400 |
10-833 mA |
10-667 mA |
30-420 mA |
10-420 mA |
10 to 700 mA |
Max scan volume, (cm) |
60 |
175 |
175 |
190 |
200 |
180 |
180 |
170 |
170 |
170 |
170 |
|
Max load capacity with accuracy, (kg) |
N/A |
205 +/- 0.25, option 230 +/- 0.25 |
205 +/- 0.25, option 230 +/- 0.25 |
660 lb/300 kg |
250 |
227 |
227 |
205 standard, 300 option |
205 standard, 300 option |
205 standard, 300 option |
205 standard, 300 option |
200 |
Scan FOVs, (cm) |
25.3 |
18, 24, 32, 40, 55, 70, 85 (extended) |
18, 24, 32, 40, 50 |
50 (extended FOV 85) |
2 to 50 |
2 to 50 |
2 to 50 |
25, 33, 50 |
50 |
50 |
50 |
2 to 50 |
Reconstruction matrices |
512 x 512, 1024 x 1024 |
512 x 512 |
512 x 512 |
512 x 512 |
512 x 512 |
512 x 512 |
512 x 512 |
512 x 512, 768 x 768, 1,024 x 1,024 |
512 x 512, 768 x 768, 1,024 x 1,024 |
512 x 512, 768 x 768, 1,024 x 1,024 |
512 x 512, 768 x 768, 1,024 x 1,024 |
512 x 512 |
Dose-modulation technique |
RadRedux noise reduction |
Yes |
Yes |
x, y, z dose modulation |
3D mA modulation |
3D mA modulation |
3D mA modulation |
Yes |
Yes |
Yes |
Yes |
3D AEC modulation |
Suggested room size (m2) |
N/A |
21 (19 min.) |
21 (19 min.) |
≥20.65m2 |
≥35 |
≥27 |
≥27 |
27.6 |
27.6 |
27.6 |
27.6 |
≥ 35 m2 recommended
for system |